# -*- coding: utf-8 -*-
# doc / uidoc / __revit__ / selection() are pre-loaded.
from Autodesk.Revit.DB import FilteredElementCollector, BuiltInCategory
def audit_walls(doc):
walls = (FilteredElementCollector(doc)
.OfCategory(BuiltInCategory.OST_Walls)
.WhereElementIsNotElementType()
.ToElements())
for w in walls:
if w.LookupParameter("Fire Rating") is None:
print("Missing rating:", w.Id)
audit_walls(doc)
INTERACTIVE CONSOLE
Clear Output
Reset Session
Script Reader console — Python 3.4 (IronPython 3.4.2)
doc / uidoc / __revit__ / selection() / s0() pre-loaded; alert() prints here; quit() closes the window.
── Running wall_audit.py ──
Missing rating: 883412
Missing rating: 883910
── Finished OK ──
>>> len(selection())
3